The relationship is a multiplication, not a subtraction — and getting that backwards is the most common mistake in rentable-area explainers.
Almost every arithmetic error in a "rentable vs usable" explainer comes from the same place: treating the load factor as something you subtract, when it's something you multiply by. Get that one relationship right and the rest follows.
Usable square footage (USF) is the area a tenant occupies exclusively. Rentable square footage (RSF) is usable square footage plus that tenant's allocated share of the building's common area — corridors, lobbies, shared restrooms, mechanical space. The load factor is the ratio between the two: RSF ÷ USF.
| Area type | Area (SF) | Notes |
|---|---|---|
| Usable square footage (USF) | 10,000 SF | Tenant's exclusive area |
| Load factor | 1.15 | RSF ÷ USF |
| Rentable square footage (RSF) | 11,500 SF | USF × load factor |
| Common area allocation | 1,500 SF | RSF − USF |
| Loss factor | 13.0% | (RSF − USF) ÷ RSF |
A load factor of 1.15 means rentable area is 15% larger than usable area for that space — not that 15% of rentable area is somehow "missing." That second framing is the loss factor, a related but different number: (RSF − USF) ÷ RSF. For a load factor of 1.15, the loss factor works out to about 13%, not 15% — mixing the two up is the single most common mistake in rentable-area explainers, including the arithmetic errors that show up surprisingly often in broker blog posts on this exact topic.
A full-floor tenant occupying an entire floor typically has a lower load factor than a tenant sharing that same floor with several others, because a full-floor tenant effectively "contains" the floor's own corridors and shared restrooms within their own space, leaving only the building-wide allocation (lobby, building mechanical, shared amenities) to add on top. A multi-tenant floor instead splits that floor's own common area across each tenant first, then adds the building-wide share on top of that — which is why two suites of the identical size, on different floors of the same building, can carry different load factors.
The formula above is the shape of the relationship, but what actually counts as "common area" — and therefore what the specific load factor is — depends on which standard measured the building. BOMA Office, BOMA Industrial, and REBNY each draw the usable/common line somewhat differently; retail and multifamily standards don't apply this load-factor step to their base figure at all. See all standards for the specifics, or how to check a REBNY figure against your own floor if the building is measured under REBNY instead of BOMA.
No — rentable square footage is always usable square footage plus an added share of common area, so rentable is equal to or larger than usable, never smaller.
Usually because one has a full floor and the other shares the floor with other tenants. A full-floor tenant's usable area already includes the floor's own common area, so their load factor reflects only the building-wide allocation; a multi-tenant floor splits that floor's common area across tenants as well, which can produce a different ratio for each.
If it's inside your demised space and not one of the standard's specific rentable exclusions (like a major vertical penetration), it's typically counted as tenant area, which is part of occupant/usable area — and therefore part of rentable area too.
For a sanity check, yes — see the rentable area calculator. For an actual lease or appraisal number, the load factor has to come from that specific building's own measured results, not a typical industry figure, because it depends on the building's own layout and common area.
RentableArea.com produces these results from your own measured floor plan, building by building.