REBNY
REBNY treats rentable area as a number the landlord declares, not one computed from geometry. Try the calculator below with a sample floor, or your own drawn usable area and loss factor — add-on factor, loss factor and target rentable area recompute from each other as you type.
REBNY — the Real Estate Board of New York — treats rentable area differently from BOMA: not as a figure computed from geometry, but as a number the landlord or broker declares. That changes what "checking" a REBNY rentable square footage figure actually means. The calculator below walks through that check on one NYC office floor; the rest of this page explains the REBNY rules behind it.
The floor-plan figures below are pre-loaded from a sample floor so you can see the calculator work immediately — turn on "Use my own figures" to type in your own drawn usable area, net usable area and retail area instead. Add-on factor, full-floor loss factor, multi-tenant loss factor and target rentable area recompute from each other live: change any one of the four and the other three follow the same public identity, rentable = usable ÷ (1 − loss factor).
REBNY's own published text names no loss-factor percentage anywhere — not 27%, not any other figure. The 27% shown above by default is a market convention compiled from secondary sources for NYC office space, not a value REBNY itself sets or recommends — change it to whatever figure your own lease or broker has quoted.
Once you have both numbers, two different ratios are commonly quoted, and they use different denominators — mixing them up is the most common error in a REBNY check:
A multiplier on usable area. Denominator is usable area. A load factor of 1.35 means the quoted rentable figure is 35% larger than the usable area you measured.
The share of the quoted rentable figure that isn't your own exclusive space. Denominator is rentable area — the larger of the two numbers — so loss factor is always a smaller percentage than load-factor-minus-one for the same floor.
On a single-tenant floor, one tenant's usable area is close to the floor's entire usable area, so a usable-area-vs-quoted-rentable check is reasonably direct. On a multi-tenant floor, REBNY's own method deducts the floor's corridor area (including toilets and supply rooms) and apportions it back across every suite on that floor, in proportion to each suite's own net usable area — not just the one suite you may have drawn or measured. Checking a single suite's own outline against a quoted rentable figure, without the floor-wide inputs REBNY's apportionment formula calls for (the floor's total corridor area and every other suite's net usable area), will not reliably reproduce the landlord's number — a gap there is not automatically an error, it may just mean the one-suite check is missing those floor-wide inputs.
A load or loss factor implied from your measured usable area and the landlord's quoted rentable area is useful: it tells you whether the quoted figure is in a plausible range for a floor like yours, and gives you a specific number to ask about. It is not, by itself, independent proof that the landlord's figure is wrong, or a reproduction of the full REBNY calculation for that floor — a lease dispute over square footage still needs the floor-wide inputs REBNY's own rules call for, particularly on a multi-tenant floor.
REBNY's own text works from a short, fixed deduction list, not a BOMA-style two-tier "common area" classification. Before any apportionment, REBNY subtracts public elevator shafts and their machine rooms, public stairs, qualifying HVAC equipment, fire towers, and main telephone/electric switchgear rooms — all with their enclosing walls — from every floor's usable area, single- or multi-tenant. On a multi-tenant floor only, REBNY additionally deducts the corridor area (including toilets and supply rooms) and apportions it back to each suite in proportion to that suite's own net usable area. REBNY's text does not name or define a "Floor Common Area" or "Building Common Area" category the way BOMA (ANSI/BOMA Z65.1) does — those are BOMA's terms, for a different method, named here only to contrast with REBNY's own deduction-and-apportionment language.
Under REBNY, retail and storage area is measured straight to its own rentable figure, with no loss factor applied — it never enters the office usable/rentable calculation at all. That's why the calculator above adds retail area at 100% on top of the office target rentable area, rather than running it through the add-on or loss-factor fields: REBNY produces office and retail/storage rentable area as two separately-produced figures, and its published text does not define a formula for combining them into one building-wide total.
See how to audit the square footage in your lease if a quoted loss factor doesn't match what your own floor-level check supports.
No. BOMA derives rentable area from measured geometry through a computed allocation ratio. REBNY standardizes usable area only; rentable area is instead a number the landlord or broker establishes, typically by applying a declared loss factor to usable area — REBNY's own text never publishes a formula or percentage for deriving it. That is why checking a REBNY figure starts from your own floor's drawn usable area, not from a formula that derives rentable area independently.
It's the relationship between a usable area you drew or measured yourself and a rentable area the landlord quoted — nothing more. Computing it tells you whether the quoted figure is consistent with a typical declared loss factor for that kind of floor. It does not, on its own, prove the landlord's number is wrong; see "a check, not proof" below.
Only with more care. On a single-tenant floor, the suite's usable area is close to the whole floor's usable area, so the check is fairly direct. On a multi-tenant floor, REBNY deducts the floor's corridor area (including toilets and supply rooms) and apportions it back across every tenant on that floor in proportion to each suite's own net usable area — so a single suite's own outline, without the floor's total corridor area and every other suite's net usable area, is not enough to establish that suite's usable area on its own.
No. REBNY doesn't define a "Floor Common Area" or "Building Common Area" split — that two-tier classification is BOMA's (ANSI/BOMA Z65.1) own terminology, not REBNY's. REBNY instead works from a fixed list of building-service deductions (public elevator shafts, public stairs, qualifying HVAC, fire towers, main telephone/electric switchgear rooms) that come out of usable area on every floor, plus a separate corridor-area apportionment step that applies only on multi-tenant floors.
It doesn't go through the office usable/rentable pipeline at all. Retail and storage area is measured directly to its own rentable figure with no loss factor applied. REBNY produces office and retail/storage rentable area as two separate figures — its published text doesn't define a formula for combining them into one building-wide total.
Upload a floor plan and RentableArea.com produces the area totals and load factor for you — no spreadsheet to build by hand.