BOMA Industrial 2019
One Global Summary of Areas now computes both single-occupant and multi-occupant rentable area for warehouse and industrial buildings.
ANSI/BOMA Z65.2-2019 measures industrial buildings — warehouse, distribution and light-manufacturing space — on one unified Global Summary of Areas, replacing the older standard's split between an Exterior Wall method and a Drip Line method.
The 2019 edition computes a Single Occupant Rentable Area directly from Boundary Area less rentable exclusions, and a separate Multi-Occupant Rentable Area that runs the building's occupant and amenity areas through the same kind of Floor Allocation Ratio and Building Allocation Ratio used in BOMA Office, producing a load factor specific to the building. Both figures appear in the same Global Summary of Areas, so a building leased to one tenant and a building leased to several don't need two different, incompatible measurement approaches.
| Area type | Area (SF) | Notes |
|---|---|---|
| Boundary Area (IPMS 1 – Industrial) | 140,000 | Outer building footprint |
| Less: rentable exclusions | (6,500) | Docks, major vertical penetrations |
| Single Occupant Rentable Area | 133,500 | For a single-tenant lease |
| Occupant Area + Building Amenity Area | 128,000 | = Floor Usable Area |
| Floor/Building Allocation Ratio applied | 1.042 | Spreads service + amenity area |
| Multi-Occupant Rentable Area | 133,400 | For a multi-tenant lease |
Always confirm which edition a lease or appraisal names before comparing figures across buildings. See rentable vs usable square footage for the underlying relationship this standard builds on.
The pre-2019 industrial standard split into two separate methods — an Exterior Wall method and a Drip Line method. The 2019 edition replaces that split with one unified Global Summary of Areas that computes both a Single Occupant Rentable Area and a Multi-Occupant Rentable Area side by side on the same sheet, so a building doesn't need two incompatible sets of results depending on how it's leased.
This page covers ANSI/BOMA Z65.2-2019, the edition in wide use in existing leases today; always check which edition a lease or measurement report names before comparing figures across buildings.
Structurally, yes — the 2019 standard follows the same floor/building allocation shape as BOMA Office, with its own Floor Allocation Ratio and Building Allocation Ratio producing a load factor, just applied to industrial space categories like dock area and clear-height warehouse space rather than office floor plates.
Upload a floor plan and RentableArea.com produces the area totals, load factor, and Global Summary of Areas for you — no spreadsheet to build by hand.