BOMA Multifamily & Hospitality 2023

BOMA Multifamily & Hospitality 2023: Enclosed Living Area

One combined standard measures apartment units and hotel rooms through the same Global Summary, with no load factor applied to the base figure.

Measures to ANSI/BOMA Z65.4-2023. RentableArea.com is not affiliated with or endorsed by BOMA International.

Status: supported — implemented and verified against this standard's own published worked examples, and live today for a real building.

ANSI/BOMA Z65.4-2023 covers multifamily and hospitality properties under one combined standard — the same Global Summary structure serves an apartment building measured per unit and a hotel measured per room or key.

One standard, two kinds of buildings

Rather than splitting multifamily and hospitality into separate standards, the 2023 edition defines a single "Enclosed Living Area" input that both building types feed into, each in its own natural unit — apartment units for multifamily, rooms or keys for hospitality — before the same downstream Global Summary columns apply.

Three ways to measure the same unit

A unit's Enclosed Living Area can be established through a Gross Area Method, or a Net Area Method with two further variants — Inside Net and Centerline Net, which differ in how they treat the wall itself. All three converge on the same downstream Global Summary once the figure is set, so the choice is about measurement convention, not a different final structure.

No rentable area or load factor on the base sheet, by design

Unlike office measurement, this standard's base Global Summary stops at Enclosed Living Area and related categories without grossing it up through a load factor — applying a load factor directly to residential or hospitality units isn't how that space is typically transacted. An enhanced sheet does carry an informational Inter-Building Load Factor for campus-level expense allocation, but it's a CAM-support figure, not a computed rentable area, and there's no Capped Load Factor concept here for the same reason — there's no "natural" load factor to cap against.

See inter-building amenity and service area allocation for how shared campus space is handled across standards that do use this kind of mechanism.

Frequently asked questions

Does the 2023 standard treat apartments and hotels as different standards?

No — Multifamily and Hospitality share one combined standard and one Global Summary. A units-based apartment building and a rooms/keys-based hotel are measured through the same downstream Global Summary columns, just with different inputs feeding into "Enclosed Living Area."

Is there a rentable area and load factor figure on this standard's base sheet?

No — like retail, the base sheet deliberately stops at Enclosed Living Area and related categories, without applying a load factor to produce a separate rentable figure. Applying a load factor directly to residential or hospitality units isn't typically how that space is transacted.

How is a unit's area actually measured?

Three input conventions are available for the same "Enclosed Living Area" figure: a Gross Area Method, and a Net Area Method with two sub-variants (Inside Net and Centerline Net). All three feed the same downstream Global Summary once the unit area is established.

What's the Inter-Building Load Factor column for, if there's no base rentable figure?

The standard's enhanced sheet includes an informational Inter-Building Load Factor (IBLF) for allocating shared campus-level space across buildings for expense purposes — it supports CAM-style allocation, not a computed rentable-area figure, and this standard has no Capped Load Factor concept at all for the same reason.

See this standard applied to your own building

Upload a floor plan and RentableArea.com produces the area totals, load factor, and Global Summary of Areas for you — no spreadsheet to build by hand.