BOMA Office 2017
ANSI/BOMA Z65.1-2017 offers two independent calculation paths, Method A and Method B, for the same office floor plan — here's what actually differs between them.
The 2017 BOMA office standard (ANSI/BOMA Z65.1-2017) is still the edition behind most in-force office leases, and it offers two independent ways to turn a floor plan into a Global Summary of Areas: Method A and Method B. They start from the same measured geometry and land on the same basic idea — usable area plus a share of common area equals rentable area — but they get there differently enough that a figure under one method won't match the same floor under the other.
Method A works from the building's own boundary inward. Boundary Area, less rentable exclusions like major vertical penetrations, parking, and occupant storage, gives the Floor Rentable Area. Inside that, Tenant Area plus Tenant Ancillary Area gives Occupant Area, and adding Building Amenity Area gives Floor Usable Area. A Floor Allocation Ratio spreads each floor's own common area across its occupants, and a separate Building Allocation Ratio then spreads building-wide amenity and service area — the lobby, the fitness center, the loading dock — across every floor. The result is Load Factor A: Rentable Area divided by Occupant Area.
| Area type | Area (SF) | Notes |
|---|---|---|
| Boundary Area | 12,500 | Outer face of exterior walls |
| Less: major vertical penetrations, parking, storage | (450) | Rentable exclusions |
| Floor Rentable Area | 12,050 | Boundary less exclusions |
| Tenant Area + Tenant Ancillary Area | 9,800 | = Occupant Area |
| Building Amenity Area (allocated) | 350 | Lobby, fitness center share |
| Floor Usable Area | 10,150 | Occupant + building amenity |
| Floor Allocation Ratio | 1.230 | Floor Rentable ÷ Occupant Area |
| Rentable Area (Load Factor A) | 12,050 | Occupant Area × Floor Allocation Ratio |
Method B skips the per-floor allocation step and produces a single load factor for the whole building. It also introduces an input Method A has no equivalent for: Base Building Circulation, the primary corridors and paths of travel that serve the building generally rather than any one floor. Because the two methods allocate area differently, Method B's single building-wide number and Method A's per-floor numbers for the same building are not the same figure, and shouldn't be compared as if they were.
The 2017 standard explicitly permits a landlord to put a ceiling — a Capped Load Factor — on what a tenant pays for in a lease, separate from the method's own computed, actual load factor. The rule runs one direction only: a cap can sit below the computed figure (a landlord absorbing some common area cost), but it can never legitimately sit above it. A "capped" load factor that's actually higher than the real computed number isn't a BOMA figure at all.
See rentable vs usable square footage for a plain walk-through of the usable-to-rentable relationship these methods both build on, or office rentable area under the 2024 BOMA office standard for what changed in the next edition.
Method A builds Rentable Area up floor by floor, with a Floor Allocation Ratio for each floor and a separate Building Allocation Ratio that spreads building-wide amenity and service area across every floor — producing Load Factor A as Rentable Area divided by Occupant Area. Method B instead uses a single, building-wide load factor and asks for one input Method A doesn't use at all: Base Building Circulation, the primary corridor and path-of-travel area outside any one tenant's floor. Both methods are valid ways to measure the same building; they are not interchangeable mid-building.
Within limits. The 2017 office standard (§5.4) lets a landlord or lease assign a Capped Load Factor to a tenant's occupant area — but that cap can never legitimately exceed the method's own computed, actual load factor. A cap above the computed figure isn't BOMA-compliant, whatever the lease says.
Neither is inherently larger — they allocate the same underlying areas differently, so the two methods can produce different rentable area figures for the identical floor plan. That's exactly why the standard requires naming which method a figure uses; "11,500 SF rentable" means nothing on its own.
BOMA 2017 is still the most common edition in active leases, though BOMA 2024 is the current edition for new measurements — see what changed from 2017.
Upload a floor plan and RentableArea.com produces the area totals, load factor, and Global Summary of Areas for you — no spreadsheet to build by hand.